This analyzer is used as end of line control for electro mechanic components with electric motors, with or without mechanical reduction. While the motor is running at nominal speed, a spectrum and temporal analysis of the sound as well as a current consumption test is performed. Statistical analysis of the data acquired is also performed real-time, expediting the PASS/FAIL decision of the DUT.
When the environmental noise of the production line can disturb the data acquisition, an isolation chamber with enough attenuation is mandatory. Attenuation level depend either on the expected noise level of the DUT or on the environmental noise level.
The module features Ethernet port for automatic result data transmission through FTP. When there’s no Ethernet connection available, a USB port can be used to store the result data to an external HDD.
Features | Application | |
Power supply | 230 V 50-60 Hz | Failures detection in production lines for DUTs with electricmotors |
Ordering information
Description | P/N |
Sound harmonics and current analyzer7405.01 | H7405 0100 |
ICO Preamplifier µphone | 300225 |
Portable acoustic calibrator | 300226 |
Programmable power supply (dependson DUT specs) | On Request |
Acoustic Isolation Chamber | On Request |